Automated Extraction | Manual Extraction | ||||
---|---|---|---|---|---|
MagNA Pure 96 System** |
MagNA Pure 24 System** |
MagNA Pure LC 2.0 System* | MagNA Pure Compact System* | High Pure Kits | |
# of Samples | 1-96 samples per run | 1-24 samples per run | 1-32 samples per run | 1-8 samples per run | Up to 250 isolations per kit |
Run Time | ~1 hour | ~70 min | ~1 hour | ~30 min | Less than 20 min |
Starting Samples | Whole Blood, Plasma, Serum, Cell Culture, Tissue, Body Fluids, Fresh Frozen and FFPE Tissue, Swab, Stool, Sputum | ||||
Nucleic Acid Targets | Genomic and Bacterial DNA, Viral DNA/RNA, Plasmid DNA and Total RNA |
* For general laboratory use
** For in vitro diagnostic use

Lab Developed Testing Solutions
Develop your lab, your way.

Breakthroughs have a beginning
Start here. Go Anywhere.

Genomic Workflow Publication Database
Research articles to inspire.
MagNA Pure 96 System
Designed for an accelerated workflow
The MagNA Pure 96 System is optimized for high-throughput nucleic acid purification – 96 samples extracted in less than one hour. Requiring minimal setup with the help of prefilled reagent kits, preloaded protocols for a broad range of sample types, and deck surveillance, the MagNA Pure 96 maximizes productivity and dramatically reduces handling errors.
For in vitro diagnostic use.
Learn MoreMagNA Pure 96 Protocols
Available for Download
The MagNA Pure 96 System has new and improved protocols. Now optimised for use in sequencing, the MagNA Pure Systems can ensure reliable sequencing results from the start.
Learn MoreMagNA Pure 96 Reagents
# of Isolations | Target | Starting Material | Product No. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Whole Blood | Plasma | Cell Culture | Serum | Body Fluids | Fresh Frozen Tissue | FFPE Tissue | Swab | Stool | Sputum | ||||
MagNA Pure 96 DNA and Viral Nucleic Acid Small Volume Kit | 3x192 (200 µL) | Genomic DNA | X | X | X | X | 06543588001 | ||||||
Bacterial DNA | X | X | X | X | X | X | X | X | |||||
Viral DNA/RNA | X | X | X | X | X | X | X | X | |||||
MagNA Pure 96 DNA and Viral Nucleic Acid Large Volume Kit | 3x96 (0.5 mL) 3x48 (1 mL) | Cell-free NA | X | 06374891001 | |||||||||
Genomic DNA | X | X | X | ||||||||||
Bacterial DNA | X | X | X | X | X | X | X | X | |||||
Viral RNA/DNA | X | X | X | X | X | X | X | X | |||||
MagNA Pure 96 Cellular RNA Large Volume Kit * | 3x96 or 3x48 | Total RNA | X | X | X | X | 05467535001 | ||||||
X: Roche Supported Protocols |
Lysis Buffer |
Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure cfNA Buffer set | upto 96 isolations | External lysis buffer to enable the isolation of cell-free nucleic acid (cfNA) | 07794398001 |
MagNA Pure 96 External Lysis Buffer |
100 mL |
External lysis buffer for Whole Blood, Plasma and Serum samples |
|
MagNA Pure 96 Bacterial Lysis Buffer |
20 mL |
External lysis buffer for various sample types with bacterial and viral targets |
|
MagNA Pure 96 DNA Tissue Lysis Buffer |
100 mL |
External lysis buffer for Tissue samples (FFPE and Fresh Frozen) |
|
S.T.A.R. Buffer (Stool Transport and Recovery)† |
100 mL |
External lysis buffer for Whole Blood, Plasma and Serum samples |
03335208001 |
MagNA Pure 96 Consumables
Consumables for the MagNA Pure 96 |
Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure 96 Processing Cartridge |
36 cartridges |
Sample Input and extraction processing deep well plate |
|
MagNA Pure 96 Output Plate |
60 plates |
Eluate Collection plate |
|
MagNA Pure Tip 1000 µL |
3,840 filter tips |
Disposable tips (1000 µL) with aerosol filters |
|
MagNA Pure Sealing Foil |
100 foils |
Foils for sealing of reagent trays, output plate and processing cartridge |
|
MagNA Pure 96 Internal Control Tube |
150 tubes |
Barcoded tubes for automated processing of internal controls |
MagNA Pure 96 Accessories
Pack Size |
Description |
Product No. |
|
---|---|---|---|
MagNA Pure 96 Drop Catcher |
10 drop catchers |
Replacement accessory for MagNA Pure 96 maintenance and cleaning |
|
MagNA Pure 96 Reagent Loop Unit |
1 reagent loop |
MagNA Pure 96 Reagent Loop Unit for replacement |
|
MagNA Pure 96 Barcode Scanner |
1 barcode scanner |
MagNA Pure 96 Barcode Scanner for Replacement |
|
MagNA Pure 96 Tip Rack |
1 tip rack |
MagNA Pure 96 Tip Rack for Replacement |
|
MagNA Pure 96 Bottle Rack |
1 bottle rack |
MagNA Pure 96 Bottle Rack for Replacement |
|
MagNA Pure 96 Needle Set of 4 |
1 set |
4 Needles/Set, MagNA Pure 96 reagent pipetting head needles for replacement |
|
MagNA Pure 96 Purification Rack |
1 purification rack |
MagNA Pure 96 Purification Rack for replacement |
|
MagNA Pure 96 Reagent Rack |
1 reagent rack |
MagNA Pure 96 Reagent Rack for Replacement |
|
MagNA Pure 96 Waste Rack |
1 waste rack |
MagNA Pure 96 Waste Rack for Replacement |
|
MagNA Pure 96 Internal Waste Container |
1 waste container |
MagNA Pure 96 Internal Waste Container for replacement |
|
MagNA Pure 96 Waste Cover |
1 waste cover |
MagNA Pure 96 Waste Cover for replacement |
|
MagNA Pure 96 Plate Holder |
1 plate holder |
Plate holder for predefined custom plates as mentioned in the Operator's |
|
MagNA Pure 96 LightCycler® 480 Adapter |
1 adapter |
Adapter plate for Support of LightCycler® 480 Multiwell Plate |
|
MagNA Pure 96 Archive Plate Adapter 4S |
1 adapter |
Adapter plate for Support of 96-well plates with non-snap-lock tubes |
MagNA Pure 96 Software
The MagNA Pure 96 System is currently on software version 3.0.1. All purification and PCR Setup protocols are updated with this current software. If a software version earlier than v3.0.1 is installed on your MagNA Pure 96 Instrument, please contact Roche to set up a visit by a Roche service engineer.
MagNA Pure 24 System
Enter a new world of productivity
The MagNA Pure 24 System is a fully-automated clinical nucleic acid extraction system that brings you walkaway automation, designed to minimize user intervention and extraction-to–extraction variability. In addition to providing quality purified eluates, the MagNA Pure 24 System offers onboard primary-sample handling and mixed-batch sampling for up to 24 samples per run.
For in vitro diagnostic use.
Learn MoreMagNA Pure 24 Product Video
See it in action
Start here. Go anywhere.
For years, molecular testing laboratories have trusted the MagNA Pure family to dramatically reduce handling errors with reliable and simplified sample preparation. Building on this legacy, discover the MagNA Pure 24 System by traveling inside to follow a sample’s journey and see how you can be confident from start to finish.
MagNA Pure 24 Protocols
Available for Download
The MagNA Pure 24 System has new and improved protocols. Now optimised for use in sequencing, the MagNA Pure Systems can ensure reliable sequencing results from the start.
Learn MoreMagNA Pure 24 Reagents
The MagNA Pure 24 Total Nucleic Acid Kit eliminates unnecessary complexity by enabling extraction of nucleic acids from 10 different sample types with one simple reagent kit. It is sealable for later use, barcoded for inventory tracking, and compatible with a multitude of external lysis buffer to expand the range of applications.
# of Isolations | Target | Starting Material | Product No. | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Whole Blood | Plasma | Serum | Fresh Frozen Tissue | Urine | Stool | Others* | Cultured Cells | ||||
MagNA Pure 24 Total NA Isolation Kit** | 96 small volume (200 µL) | Genomic DNA and bacterial, fungal or viral NA | X | X | X | X (up to 5 mg) | X | X | X | X (up to 105 cultured cells) | 07658036001 |
72 large volume (500 µL, 1000 µL) | X | X | X | X | X | X | X (up to 106 cultured cells) | ||||
72 extra large volume (2000 µL, 4000 µL) | Human cell-free nucleic acid | X | |||||||||
X: Roche Supported Protocols | |||||||||||
*Other human sample types include Bronchoalveolar lavage and Swab. |
** MagNA Pure 24 Total NA Isolation Kit is for in vitro diagnostic use.
Additional Reagents or Lysis Buffers |
Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure 24 MGP Set | 12 tubes | Additional magnetic glass particles for isolations of nucleic acids. Single use | 07806361001 |
MagNA Pure cfNA Buffer Set |
Up to 96 isolations |
For the isolation of cell-free nucleic acids from plasma samples |
|
MagNA Pure LC Total Nucleic Acid Isolation Kit – Lysis/Binding Buffer Refill |
100 mL |
For external lysis protocols |
|
MagNA Pure Bacteria Lysis Buffer |
20 mL |
For the isolation of bacterial, fungal, and viral nucleic acids |
|
MagNA Pure DNA Tissue Lysis Buffer |
100 mL |
For the isolation of nucleic acids from fresh frozen tissue |
|
S.T.A.R. Buffer (Stool Transport and Recovery Buffer) | 100 mL | For stabilization, transport and recovery of nucleic acids in stool samples | 03335208001 |
Additional Reagents and Lysis Buffers are for general laboratory use unless otherwise noted.
MagNA Pure 24 MGP Set is for in vitro diagnostic use.
MagNA Pure 24 Consumables
Consumables for the MagNA Pure 24 System |
Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure 24 Processing Cartridge |
48 cartridges |
Allows processing of 8 samples in parallel and holds pipetted samples and reagents during processing |
|
MagNA Pure 24 Tip Park - Piercing Tool |
48 processing tip parks and 50 piercing tools |
Holds pipette tips used for sample pipetting and processing into the processing station adapter during a run |
|
MagNA Pure 24 Piercing Tool |
50 piercing tools |
Used to pierce sealed reagent cassettes in order to enable reagent pipetting |
|
MagNA Pure Tip 1000 µL |
40 x 96 tips |
Disposable tips (1000 µL) with aerosol filters |
|
Tip CORE TIPS with Filter, 50 µL ** |
60 x 96 tips |
Disposable tips (50 µL) with aerosol filters |
|
MagNA Pure Sealing Foil ** |
100 foils |
Foils for sealing of reagent trays, output plate and processing cartridge |
|
MagNA Pure Tube 2.0 mL ** |
350 (10 x 35) tubes |
Barcoded tubes used as secondary tubes, user-defined internal control tubes, and output tubes |
|
FrameStrip® with flat caps - Low profile ** |
120 tube strips |
8-tube strips to collect and store eluates of up to 50 μL. Also compatible with the LightCycler® 480 and LightCycler® 96 real-time PCR Systems |
|
FrameStrip® with flat caps - High profile ** |
120 tube strips |
8-tube strips to collect and store eluates of up to 150 μL |
Consumables are for in vitro diagnostic use unless otherwise noted.
** For General Laboratory Use
MagNA Pure 24 Accessories
Accessories for MagNA Pure 24 System |
Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure 24 Reagent Rack |
1 reagent rack |
Rack to load reagents (such as MGP) onto the instrument |
|
MagNA Pure 24 Sample Rack |
1 sample rack |
Holds up to 24 sample tubes (primary tubes with 13-16.2 mm outer diameter) |
|
MagNA Pure 24 Sample Rack Adapter |
1 rack with 24 adapters |
Holds up to 24 sample tubes and comes with 24 sample tube adapters (primary tubes or MagNA Pure Tubes 2.0 mL) |
|
MagNA Pure 24 Processing Station Adapter |
3 processing station adapters |
Processing station adapter for MagNA Pure 24 Processing Cartridge, MagNA Pure 24 Tip Park, and MagNA Pure 24 Liquid Waste Insert |
|
MagNA Pure 24 Tip Waste Container |
1 tip waste container |
Tip waste container |
|
MagNA Pure 24 Liquid Waste Insert |
48 liquid waste inserts |
Placed into the liquid waste reservoir of the processing station adapter to collect liquid waste. The liquid waste inserts can also be easily sealed for disposal if needed |
|
MagNA Pure 24 Reagent Tip Park |
1 reagent tip park |
Tip park for reagents |
|
MagNA Pure 24 Output Adapter 18mm |
1 adapter |
Loaded on the cooling station to hold 18-mm output consumable adapters (such as MagNA Pure Tubes 2.0mL) |
|
MagNA Pure 24 Output Adapter 9mm |
1 adapter |
Loaded on the cooling station to hold 9-mm output consumable adapters (such as 8-tube strips) |
|
MagNA Pure 24 Down Holder Frame |
1 frame |
Downholder frame for 8-tube strips (output consumables) |
|
MagNA Pure 24 Post Elution Adapter |
1 adapter |
Loads tubes and 8-tube strips used in post elution runs in the cooling station of the instrument |
All accessories are for in vitro diagnostic use.
MagNA Pure 24 Software
The MagNA Pure 24 System is currently on software version 1.0.
If you need assistance to update your system software, please contact your local Roche representative.
MagNA Pure LC 2.0 System
The legacy continues.
he MagNA Pure LC 2.0 System is a mid-throughput system built on the reliability of the MagNA Pure LC System technology. The same nucleic acid purity, reproducibility for downstream genomic workflows, and now with improved software, touchscreen interface and enhanced data management capabilities.
For general laboratory use.
Learn MoreMagNA Pure LC 2.0 Reagents
MagNA Pure LC 2.0 Consumables
Pack Size |
Description |
Product No. |
|
---|---|---|---|
MPLC Reagent Tub (large) |
120 tubs |
MagNA Pure LC Reagent tub with a capacity of 100 mL |
|
MPLC Reagent Tub (medium) |
150 tubs |
MagNA Pure LC Reagent tub with a capacity of 20 mL |
|
MPLC Reagent Tub (small) |
150 tubs |
MagNA Pure LC Reagent tub with a capacity of 3.5 mL |
|
MPLC Tub Lid (large) |
120 lids |
Lid for MPLC Reagent Tub (large) with tip access perforations |
|
MPLC Tub Lid (small, medium) |
300 lids |
Lid for MPLC Reagent Tub (Small, Medium) with tip access perforations |
|
MPLC Tub Lid Seal |
400 seals |
Seals for all MagNA Pure LC Tubs. Can be used as a liquid drop catcher |
|
MPLC Sample Cartridges |
120 cartridges |
32- well cartridge for starting samples, extraction elution and storage |
|
MPLC Processing Cartridges |
160 cartridges |
Cartridges used for extraction processing |
|
MPLC Tip Stand |
200 tip stands |
Tip storage during extraction run to minimize unnecessary tip use |
|
MPLC Reaction Tip (large) |
960 tips |
Tips for extraction. The pipeting volume range is 50 to 1000 µL |
|
MPLC Reaction Tip (small) |
960 tips |
Tips for extraction. The pipeting volume range is 5 to 50 µL |
|
MPLC Waste Bottle |
40 bottles |
Collects up to 330 mL of liquid waste |
|
MPLC Medium Reagent Tub 30 |
50 tubs |
MagNA Pure LC Reagent Tub with a capacity of 30 mL |
03045501001 |
MPLC Cartridge Seal |
200 seals |
Inert adhesive film used for sealing the MPLC Sample Cartridge for storage |
|
MPLC Barcode printer ribbon |
1 ribbon |
Printer ribbon for use on MagNA Pure LC Barcode Printer TLP 2844 |
|
MagNA Pure LC 2.0 Waste Bags |
25 bags |
Waste Bags for MagNA Pure LC 2.0 Waste Box for the collection of used tip |
MagNA Pure LC 2.0 Accessories
Pack Size |
Description |
Product No. |
|
---|---|---|---|
MPLC Reagent Reservoir Rack |
1 reagent rack |
Additional rack for reagent tubs |
|
MPLC Reagent Tip Rack (Large Tips) |
1 tip rack |
MPLC Reagent Tip Rack (Large Tips) for replacement |
|
MPLC Reagent Tip Rack (Small Tips) |
1 tip rack |
MPLC Reagent Tip Rack (Small Tips) for replacement |
|
MPLC Liquid Waste Funnel |
1 funnel |
MPLC Liquid Waste Funnel for replacement |
|
MPLC Waste Bottle Tray |
1 tray |
MPLC Waste Bottle Tray for Replacement |
|
MPLC Greasing Set |
1 set |
MPLC Greasing Set for automated or manual greasing of the O-Rings |
|
MPLC O-Ring Maintenance Kit |
1 set |
Greasing vial and O-rings for replacement |
* All MagNA Pure LC2.0 Kits, Consumables and Accessories are for general laboratory use unless otherwise noted.
Download and Installation Instruction (25 KB PDF-File)
Protocols for Total Nucleic Acid Kit - High Performance, up to 200 µL sample volume (26 KB ZIP-File)
Protocols for Total Nucleic Acid Kit - High Performance, 500 µL sample volume (15 KB ZIP-File)
Protocols for Total Nucleic Acid Kit - High Performance, 1,000 µL sample volume (10 KB ZIP-File)
Note: If a software version earlier than v 1.1.24 is installed on your MagNA Pure LC Instrument, please contact Roche prior to installation of these protocols to get an update to v 1.1.24.
MagNA Pure Compact System
Benchtop extraction for up to 8 samples in ~30 minutes
With intuitive touchscreen guidance, barcode scanning of kits, and preloaded protocols, the MagNA Pure Compact System offers a simplified benchtop solution for your automated extraction needs.
For general laboratory use.
Learn MoreMagNA Pure Compact Reagents
# of isolations | Target | Starting Material | Product No. | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Whole Blood | Blood Cells | Plasma | Cell Culture | Serum | Body Fluids | Fresh Frozen Tissue | Swab | Sputum | ||||
MagNA Pure Compact NA Isolation Kit I | 32 | Genomic DNA, Bacterial DNA or Viral DNA/RNA | X | X | X | X | X | X | C | C | 03730964001 | |
MagNA Pure Compact NA Isolation Kit I- Large Volume | 32 | X | X | X | X | X | 03730972001 | |||||
MagNA Pure Compact RNA Isolation Kit | 32 | Total RNA | X | X | X | X | 04802993001 | |||||
MagNA Pure Bacteria Lysis Buffer | 20 mL | Lysis Buffer | 04659180001 | |||||||||
X : Roche Supported Protocols | ||||||||||||
C : Roche Supported Protocols in combination with the MagNA Pure Bacteria Lysis Buffer and DNA_Bacteria purification protocol |
MagNA Pure Compact Consumables
Consumables for the MagNA Pure Compact | Pack Size |
Description |
Product No. |
---|---|---|---|
MP Compact Tip Tray Kit |
10 tip trays |
Replacement accessory for Leakage Test |
MagNA Pure Compact Accessories
Accessories for the MagNA Pure Compact | Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure Compact Cartridge Rack |
1 cartridge rack |
Additional cartridge rack for use with the MagNA Pure Compact Instrument |
|
MagNA Pure Compact Drip Tray |
1 drip tray |
Additional drip tray for use with the MagNA Pure Compact Instrument |
|
MagNA Pure Compact Drop Catcher |
1 drop catcher |
Additional drop catcher for use with the MagNA Pure Compact Instrument |
|
MagNA Pure Compact Elution Tube Rack |
1 tube rack |
Additional elution tube rack for use with the MagNA Pure Compact Instrument |
|
MagNA Pure Compact Tube Rack |
1 tube rack |
Additional elution tube rack for use with the MagNA Pure Compact Instrument |
|
MagNA Pure Compact Waste Tank |
1 waste tank |
Additional waste tank for use with the MagNA Pure Compact Instrument |
* All MagNA Pure Compact Kits, Consumables and Accessories are for general laboratory use unless otherwise noted.
MagNA Pure Compact Software
The current software version for the MagNA Pure Compact is V1.1.2 which contains the latest protocols as of today. In case an update is required please contact your local service representative.
Click here for an updated version of the MagNA Pure Compact RNA Isolation Kit protocol for the isolation of RNA from 200 µL mammalian blood. Protocols for RNA Isolation Kit - Isolation of RNA from 200 µL mammalian blood (8 KB ZIP-File)
Nucleic Acid Purification Reagents
MagNA Pure 96 Reagents
# of Isolations | Target | Starting Material | Product No. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Whole Blood | Plasma | Cell Culture | Serum | Body Fluids | Fresh Frozen Tissue | FFPE Tissue | Swab | Stool | Sputum | ||||
MagNA Pure 96 DNA and Viral Nucleic Acid Small Volume Kit | 3x192 (200 µL) | Genomic DNA | X | X | X | X | 06543588001 | ||||||
Bacterial DNA | X | X | X | X | X | X | X | X | |||||
Viral DNA/RNA | X | X | X | X | X | X | X | X | |||||
MagNA Pure 96 DNA and Viral Nucleic Acid Large Volume Kit | 3x96 (0.5 mL) 3x48 (1 mL) | Cell-free NA | X | 06374891001 | |||||||||
Genomic DNA | X | X | X | ||||||||||
Bacterial DNA | X | X | X | X | X | X | X | X | |||||
Viral RNA/DNA | X | X | X | X | X | X | X | X | |||||
MagNA Pure 96 Cellular RNA Large Volume Kit * | 3x96 or 3x48 | Total RNA | X | X | X | X | 05467535001 | ||||||
X : Roche Supported Protocols |
Lysis Buffer |
Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure cfNA Buffer set | upto 96 isolations | External lysis buffer to enable the isolation of cell-free nucleic acid (cfNA) | 07794398001 |
MagNA Pure 96 External Lysis Buffer |
100 mL |
External lysis buffer for Whole Blood, Plasma and Serum samples |
|
MagNA Pure 96 Bacterial Lysis Buffer |
20 mL |
External lysis buffer for various sample types with bacterial and viral targets |
|
MagNA Pure 96 DNA Tissue Lysis Buffer |
100 mL |
External lysis buffer for Tissue samples (FFPE and Fresh Frozen) |
|
S.T.A.R. Buffer (Stool Transport and Recovery)† |
100 mL |
External lysis buffer for Whole Blood, Plasma and Serum samples |
03335208001 |
MagNA Pure 24 Reagents
The MagNA Pure 24 Total Nucleic Acid Kit eliminates unnecessary complexity by enabling extraction of nucleic acids from 10 different sample types with one simple reagent kit. It is sealable for later use, barcoded for inventory tracking, and compatible with a multitude of external lysis buffer to expand the range of applications.
# of Isolations | Target | Starting Material | Product No. | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Whole Blood | Plasma | Serum | Fresh Frozen Tissue | Urine | Stool | Others* | Cultured Cells | ||||
MagNA Pure 24 Total NA Isolation Kit | 96 small volume (200 µL) | Genomic DNA and bacterial, fungal or viral NA | X | X | X | X (up to 5 mg) | X | X | X | X (up to 105 cultured cells) | 07658036001 |
72 large volume (500 µL, 1000 µL) | X | X | X | X | X | X | X (up to 106 cultured cells) | ||||
72 extra large volume (2000 µL, 4000 µL) | Human cell-free nucleic acid | X | |||||||||
X: Roche Supported Protocols | |||||||||||
*Other human sample types include Bronchoalveolar lavage and Swab. |
** MagNA Pure 24 Total NA Isolation Kit is for in vitro diagnostic use.
Additional Reagents or Lysis Buffers |
Pack Size |
Description |
Product No. |
---|---|---|---|
MagNA Pure 24 MGP Set | 12 tubes | Additional magnetic glass particles for isolations of nucleic acids. Single use | 07806461001 |
MagNA Pure cfNA Buffer Set |
Up to 96 isolations |
For the isolation of cell-free nucleic acids from plasma samples |
|
MagNA Pure LC Total Nucleic Acid Isolation Kit – Lysis/Binding Buffer Refill |
100 mL |
For external lysis protocols |
|
MagNA Pure Bacteria Lysis Buffer |
20 mL |
For the isolation of bacterial, fungal, and viral nucleic acids |
|
MagNA Pure DNA Tissue Lysis Buffer |
100 mL |
For the isolation of nucleic acids from fresh frozen tissue |
|
S.T.A.R. Buffer (Stool Transport and Recovery Buffer) | 100 mL | For stabilization, transport and recovery of nucleic acids in stool samples | 03335208001 |
Additional Reagents and Lysis Buffers are for general laboratory use unless otherwise noted.
MagNA Pure 24 MGP Set is for in vitro diagnostic use.
MagNA Pure LC 2.0 Reagents
MagNA Pure Compact Reagents
# of isolations | Target | Starting Material | Product No. | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Whole Blood | Blood Cells | Plasma | Cell Culture | Serum | Body Fluids | Fresh Frozen Tissue | Swab | Sputum | ||||
MagNA Pure Compact NA Isolation Kit I | 32 | Genomic DNA, Bacterial DNA or Viral DNA/RNA | X | X | X | X | X | X | C | C | 03730964001 | |
MagNA Pure Compact NA Isolation Kit I- Large Volume | 32 | X | X | X | X | X | 03730972001 | |||||
MagNA Pure Compact RNA Isolation Kit | 32 | Total RNA | X | X | X | X | 04802993001 | |||||
MagNA Pure Bacteria Lysis Buffer | 20 mL | Lysis Buffer | 04659180001 | |||||||||
X : Roche Supported Protocols | ||||||||||||
C : Roche Supported Protocols in combination with the MagNA Pure Bacteria Lysis Buffer and DNA_Bacteria purification protocol |
High Pure Kits
Flexible Nucleic Acid Isolation
Fast, flexible, and easy to use, High Pure Kits facilitate nucleic acid isolation from a variety of sample materials. This proven technology offers unparalleled flexibility while delivering the high-quality results you need for your desired application.
Go Pure
Reagent Selection Guide
Not sure which kit is best for you? With the new Roche Reagent Selection guide, you can easily find which reagents are right for your applications.

Genomic Workflow Publication
The Genomic Workflow Publication Database is your source for relevant, reliable information specific to your search applications.

Instructions for Use and MSDS
Use this Search function to obtain your Instructions for Use and MSDS in a fast and easy searchable format.