{ "ProductData": { "ID": "3.5.8.1.1.1", "ProductType": "Others", "BrandName": "LightCycler® 480 Probes Master", "ProductNameAddition": "Ready-to-use hot start reaction mix for PCR using the LightCycler® 480 System", "RegulatoryDisclaimer1": "For life science research only. Not for use in diagnostic procedures.", "DisclaimerGroup1": "LSR", "RegulatoryDisclaimer2": "", "DisclaimerGroup2": null, "RegulatoryDisclaimer3": "", "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "LightCycler 480 Probes Master" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/Article_04902343001_im_en.png", "ImageType": "Image main" }, "Product2Taxomony": { "Product2TaxomonyReferences": [ { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "StructureNodeStatus": "valid", "NodeName": "LightCycler® 480 Kits", "NodeID": "06-0017" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Assays Reagents and Strips", "NodeID": "20-000-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "LightCycler", "NodeID": "230" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "valid", "NodeName": "PCR/qPCR", "NodeID": "210-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "valid", "NodeName": "Research Lab", "NodeID": "150-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Molecular", "NodeID": "100" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "valid", "NodeName": "Genotyping", "NodeID": "09-00-00" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "valid", "NodeName": "Quantitative Detection", "NodeID": "34-00-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "170-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" } ] }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "StructureNodeStatus": "valid", "NodeName": "LightCycler® 480 Kits", "NodeID": "06-0017" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Assays Reagents and Strips", "NodeID": "20-000-00" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "LightCycler", "NodeID": "230" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "valid", "NodeName": "PCR/qPCR", "NodeID": "210-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "valid", "NodeName": "Research Lab", "NodeID": "150-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Molecular", "NodeID": "100" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "valid", "NodeName": "Genotyping", "NodeID": "09-00-00" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "valid", "NodeName": "Quantitative Detection", "NodeID": "34-00-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "170-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "04887301001", "MaterialDescription": "LightCycler 480 Probes Master, 10x5 ml", "RegisteredProductName": "LightCycler 480 Probes Master", "GTIN": "04038377024455", "ProductCategoryText": "Reagents, kits", "OldMaterialNumber": "", "PackSizePIM360": "10 x 5 ml", "PackSizeDescPIM360": "2x conc.
10 x 500 reactions of 20 μl final volume each", "MaterialAnnotation": "", "ReadyForUse": "false", "OrderInformation": "" }, { "MaterialNum": "04707494001", "MaterialDescription": "LightCycler 480 Probes Master", "RegisteredProductName": "LightCycler 480 Probes Master", "GTIN": "04038377021829", "ProductCategoryText": "Reagents, kits", "OldMaterialNumber": "", "PackSizePIM360": "5 x 1 ml", "PackSizeDescPIM360": "2x conc.
5 x 100 reactions of 20 μl final volume each", "MaterialAnnotation": "", "ReadyForUse": "false", "OrderInformation": "" }, { "MaterialNum": "04902343001", "MaterialDescription": "LightCycler 480 Probes Master, 50 ml", "RegisteredProductName": "LightCycler 480 Probes Master", "GTIN": "04038377024530", "ProductCategoryText": "Reagents, kits", "OldMaterialNumber": "", "PackSizePIM360": "1 x 50 ml", "PackSizeDescPIM360": "2x conc.
5,000 reactions of 20 μl final volume each", "MaterialAnnotation": "", "ReadyForUse": "false", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ { "ProductID": "INS_445", "BrandName": "LightCycler® 480 Instrument II", "ProductNameAddition": "", "ReferenceType": "Instrument", "Classification": [ { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "417", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "230", "StructureGroupPath": "LightCycler", "StructureGroupName": "LightCycler", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "10-000-00", "StructureGroupPath": "Analyzer Instruments and Systems", "StructureGroupName": "Analyzer Instruments and Systems", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "210-00", "StructureGroupPath": "PCR/qPCR", "StructureGroupName": "PCR/qPCR", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "300-00", "StructureGroupPath": "RT-PCR/qRT-PCR", "StructureGroupName": "RT-PCR/qRT-PCR", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "170-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "160-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "055", "StructureGroupPath": "Laboratory developed testing", "StructureGroupName": "Laboratory developed testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "530", "StructureGroupPath": "Sequencing", "StructureGroupName": "Sequencing", "StructureNodeStatus": "valid" } ] } ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "en", "Value": "Store the kit at −15 to −25°C.", "Country": "XG", "Code": "Storage Conditions (Product)", "Name": "Storage Conditions (Product)" }, { "Language": "en", "Value": "
Vial / BottleCapLabelFunction/DescriptionCatalog NumberContent
1redLightCycler® 480 Probes Master, 2x conc.
  • Ready-to-use hot start PCR mix
  • Contains FastStart Taq DNA Polymerase, reaction buffer, dNTP mix (with dUTP instead of dTTP), and 6.4 mM MgCl2
04 707 494 0015 vials, 1 ml each
04 887 301 00110 vials, 5 ml each
04 902 343 0011 vial, 50 ml
2colorlessLightCycler® 480 Probes Master, Water, PCR GradeTo adjust the final reaction volume04 707 494 0015 vials, 1 ml each
04 887 301 0012 vials, 25 ml each
04 902 343 0012 vials, 25 ml each
", "Country": "XG", "Code": "Content", "Name": "Content" }, { "Language": "en", "Value": "LightCycler® 480 Probes Master is a ready-to-use reaction mix specifically developed for the hydrolysis probe detection format in multiwell plates on the LightCycler® 480 Instrument. It contains FastStart Taq DNA Polymerase for hot start PCR, which significantly improves the specificity and sensitivity of PCR by minimizing the formation of nonspecific amplification products (Chou, Q. et al., 1992, Kellogg, D.E. et al., 1994, and Birch, D.E., 1996).

FastStart Taq DNA Polymerase is a chemically modified form of thermostable recombinant Taq DNA Polymerase that shows no activity up to 75°C. The enzyme is active only at high temperatures, where primers no longer bind nonspecifically. The enzyme is fully activated (by removal of blocking groups) in a single pre-incubation step (95°C, 5 - 10 minutes) before cycling begins. Activation does not require the extra handling steps typical of other hot start techniques.

Sequence-specific detection of PCR products relies on sequence-specific oligonucleotide probes that are coupled to fluorophores. These probes hybridize to their complementary sequence in target PCR products. Probe chemistries that are suitable for use in the LightCycler® 480 Instrument include single-labeled probes, hybridization probes, and hydrolysis probes. Hybridization and hydrolysis probe chemistries use the so-called FRET principle. Fluorescence Resonance Energy Transfer (FRET) is based on the transfer of energy from one fluorophore (the donor or reporter) to another adjacent fluorophore (the acceptor or quencher).
Hydrolysis probe assays can technically be described as homogeneous 5'-nuclease assays, since a single 3'-non-extendable probe, which is cleaved during PCR amplification, is used to detect the accumulation of a specific target DNA sequence (Holland, P. M. et al., 1991). This single probe contains two labels, a fluorescent reporter and a quencher, in close proximity to each other. When the probe is intact, the quencher dye is close enough to the reporter dye to suppress the reporter fluorescent signal (fluorescent quenching takes place via FRET). During PCR, the 5'-nuclease activity of the polymerase cleaves the hydrolysis probe, separating the reporter and quencher. The reporter dye is no longer quenched and emits a fluorescent signal when excited.

The LightCycler® 480 Instrument can detect hydrolysis probes that are labeled with the reporter dyes LightCycler® Red 610, LightCycler® Red 640, LightCycler® Cyan 500, FAM, or HEX. These labeled hydrolysis probes can be used separately or in combination, which permits either single- or multicolor detection.
​​​​​​​
For multicolor hydrolysis probe assays, it is recommended to use dark quencher dyes (i.e., dye molecules which efficiently quench the fluorescence of a FRET reporter dye without emitting fluorescence themselves). Roche Life Science recommends using BHQ-2 (quenching range 550 -650 nm) for all hydrolysis probe reporter dyes listed above
", "Country": "XG", "Code": "Principle", "Name": "Principle" }, { "Language": "en", "Value": "LightCycler® 480 Probes Master is a ready-to-use reaction mix specifically developed for hydrolysis probe-based assays performed in multiwell plates using the LightCycler® 480 Instrument. It contains FastStart Taq DNA Polymerase for hot start PCR, which significantly improves the specificity and sensitivity of PCR by minimizing the formation of nonspecific amplification products.", "Country": "XG", "Code": "Product Description", "Name": "Product Description" }, { "Language": "en", "Value": "LightCycler® 480 Probes Master is designed for research studies on the LightCycler® 480 System. The LightCycler® 480 Probes Master is a ready-to-use hot start reaction mix designed specifically for detecting DNA targets with hydrolysis probes during LightCycler® 480 System PCR. However, it may be used in other types of PCR on the LightCycler® 480 System. For best results, use this master mix with LightCycler® 480 Multiwell Plates.
The kit can also help prevent carryover contamination during PCR (when used with LightCycler® Uracil-DNA Glycosylase*) or to perform the second step of a two-step RT-PCR.", "Country": "XG", "Code": "Applications", "Name": "Applications" }, { "Language": "en", "Value": "The assay time is variable, depending on the number of cycles and the annealing time.For example, for a cycling program of 40 cycles and an annealing time of 20 seconds, the LightCycler® 480 PCR run will require about 45 minutes, including 5 minutes pre-incubation time.", "Country": "XG", "Code": "Assay Time", "Name": "Assay Time" }, { "Language": "en", "Value": "Ready-to-use hot start reaction mix for PCR using the LightCycler® 480 System", "Country": "XG", "Code": "Product Characteristics", "Name": "Product Characteristics" } ] } } ] }

LightCycler® 480 Probes Master

Ready-to-use hot start reaction mix for PCR using the LightCycler® 480 System

LightCycler<sup><sup>®</sup></sup> 480 Probes Master

Ordering Information

Overview

Technical Documents

Access Material Data Sheets, Certificates of Analysis, and other product documentation.

After clicking above, you will be redirected to eLabDoc, where you can choose your local country.