{
"ProductData": {
"ID": "3.8.1.4.2.6",
"ProductType": "Others",
"BrandName": "LightCycler
® 8-Tube Strip Adapter Plate",
"ProductNameAddition": "",
"RegulatoryDisclaimer1": "For life science research only. Not for use in diagnostic procedures.",
"DisclaimerGroup1": "LSR",
"RegulatoryDisclaimer2": null,
"DisclaimerGroup2": null,
"RegulatoryDisclaimer3": null,
"SampleType": [
],
"LicenseDisclaimers": [
],
"RelatedLinks": "",
"Clone": "",
"ControlTissue": [
""
],
"ISOtypes": "",
"Species": [
""
],
"StainLocalization": [
""
],
"ProductNameGlobal": "LightCycler 8-Tube Strip Adapter Plate"
},
"ProductImageDetails": {
"ImagePath": "https://pim-media.roche.com/Images/LC 8-Tube Strip Adapter Plate.jpg",
"ImageType": "Image main"
},
"Product2Taxonomy": {
"Product2TaxonomyReferences": [
{
"StructureSystemIdentifier": "Product_Grouping",
"StructureSystemName": "Product Grouping",
"NodeID": "06-0018",
"StructureNodeStatus": "valid",
"NodeName": "LightCycler 480 System Accessories"
},
{
"StructureSystemIdentifier": "OWP_Product_Types",
"StructureSystemName": "Product Types",
"NodeID": "40-000-00",
"StructureNodeStatus": "valid",
"NodeName": "Accessories"
},
{
"StructureSystemIdentifier": "OWP_Family",
"StructureSystemName": "Product Families",
"NodeID": "230",
"StructureNodeStatus": "valid",
"NodeName": "LightCycler"
},
{
"StructureSystemIdentifier": "Product_Solutions",
"StructureSystemName": "Product Solutions",
"NodeID": "100",
"StructureNodeStatus": "valid",
"NodeName": "Molecular"
},
{
"StructureSystemIdentifier": "Lab_Type",
"StructureSystemName": "Lab Types",
"NodeID": "170-00",
"StructureNodeStatus": "invalid",
"NodeName": ""
},
{
"StructureSystemIdentifier": "Applications",
"StructureSystemName": "Applications",
"NodeID": "99-00-00",
"StructureNodeStatus": "invalid",
"NodeName": ""
},
{
"StructureSystemIdentifier": "OWP_Techniques",
"StructureSystemName": "Techniques",
"NodeID": "999-00",
"StructureNodeStatus": "invalid",
"NodeName": ""
},
{
"StructureSystemIdentifier": "Disease_Areas",
"StructureSystemName": "Disease Areas",
"NodeID": "99-00-00",
"StructureNodeStatus": "invalid",
"NodeName": ""
},
{
"StructureSystemIdentifier": "Pathogens",
"StructureSystemName": "Pathogens",
"NodeID": "99-00-00",
"StructureNodeStatus": "invalid",
"NodeName": ""
},
{
"StructureSystemIdentifier": "Health_Topics",
"StructureSystemName": "Health Topics",
"NodeID": "99-00-00",
"StructureNodeStatus": "invalid",
"NodeName": ""
}
]
},
"Product2Materials": {
"P2MaterialReferences": [
{
"MaterialNum": "06612598001",
"MaterialDescription": "LightCycler 8-Tube Strip Adapter Plate",
"RegisteredProductName": "LightCycler 8-Tube Strip Adapter Plate",
"GTIN": "04015630945122",
"ProductCategoryText": "Accessories general (hardware)",
"OldMaterialNumber": "",
"PackSizePIM360": "1 piece",
"PackSizeDescPIM360": "adapter plate
The adapter plate can be used multiple times",
"MaterialAnnotation": "",
"ReadyForUse": "undefined",
"OrderInformation": ""
}
]
},
"Product2Products": {
"Product2ProductReference": [
{
"ProductID": "INS_445",
"BrandName": "LightCycler
® 480 Instrument II",
"ProductNameAddition": "",
"ReferenceType": "Instrument",
"Classification": [
{
"IdentifierofStructureSystem": "1",
"NameofStructureSystem": "GPCH",
"StructureNodeID": "417",
"StructureGroupPath": "",
"StructureGroupName": "",
"StructureNodeStatus": ""
},
{
"IdentifierofStructureSystem": "OWP_Family",
"NameofStructureSystem": "Product Families",
"StructureNodeID": "230",
"StructureGroupPath": "LightCycler",
"StructureGroupName": "LightCycler",
"StructureNodeStatus": "valid"
},
{
"IdentifierofStructureSystem": "OWP_Product_Types",
"NameofStructureSystem": "Product Types",
"StructureNodeID": "10-000-00",
"StructureGroupPath": "Analyzer Instruments and Systems",
"StructureGroupName": "Analyzer Instruments and Systems",
"StructureNodeStatus": "valid"
},
{
"IdentifierofStructureSystem": "OWP_Techniques",
"NameofStructureSystem": "Techniques",
"StructureNodeID": "210-00",
"StructureGroupPath": "PCR/qPCR",
"StructureGroupName": "PCR/qPCR",
"StructureNodeStatus": "valid"
},
{
"IdentifierofStructureSystem": "OWP_Techniques",
"NameofStructureSystem": "Techniques",
"StructureNodeID": "300-00",
"StructureGroupPath": "RT-PCR/qRT-PCR",
"StructureGroupName": "RT-PCR/qRT-PCR",
"StructureNodeStatus": "valid"
},
{
"IdentifierofStructureSystem": "Lab_Type",
"NameofStructureSystem": "Lab Types",
"StructureNodeID": "170-00",
"StructureGroupPath": "",
"StructureGroupName": "",
"StructureNodeStatus": "invalid"
},
{
"IdentifierofStructureSystem": "Lab_Type",
"NameofStructureSystem": "Lab Types",
"StructureNodeID": "160-00",
"StructureGroupPath": "",
"StructureGroupName": "",
"StructureNodeStatus": "invalid"
},
{
"IdentifierofStructureSystem": "Applications",
"NameofStructureSystem": "Applications",
"StructureNodeID": "99-00-00",
"StructureGroupPath": "",
"StructureGroupName": "",
"StructureNodeStatus": "invalid"
},
{
"IdentifierofStructureSystem": "Disease_Areas",
"NameofStructureSystem": "Disease Areas",
"StructureNodeID": "99-00-00",
"StructureGroupPath": "",
"StructureGroupName": "",
"StructureNodeStatus": "invalid"
},
{
"IdentifierofStructureSystem": "Pathogens",
"NameofStructureSystem": "Pathogens",
"StructureNodeID": "99-00-00",
"StructureGroupPath": "",
"StructureGroupName": "",
"StructureNodeStatus": "invalid"
},
{
"IdentifierofStructureSystem": "Health_Topics",
"NameofStructureSystem": "Health Topics",
"StructureNodeID": "99-00-00",
"StructureGroupPath": "",
"StructureGroupName": "",
"StructureNodeStatus": "invalid"
},
{
"IdentifierofStructureSystem": "Product_Solutions",
"NameofStructureSystem": "Product Solutions",
"StructureNodeID": "055",
"StructureGroupPath": "Laboratory developed testing",
"StructureGroupName": "Laboratory developed testing",
"StructureNodeStatus": "valid"
},
{
"IdentifierofStructureSystem": "Product_Solutions",
"NameofStructureSystem": "Product Solutions",
"StructureNodeID": "100",
"StructureGroupPath": "Molecular",
"StructureGroupName": "Molecular",
"StructureNodeStatus": "valid"
},
{
"IdentifierofStructureSystem": "Product_Solutions",
"NameofStructureSystem": "Product Solutions",
"StructureNodeID": "530",
"StructureGroupPath": "Sequencing",
"StructureGroupName": "Sequencing",
"StructureNodeStatus": "valid"
}
]
}
]
},
"ProductSpec": [
{
"ProductSpecVariant": {
"Chapters": [
{
"Name": "Storage Conditions (Product)",
"Value": "Store at +15 to +25°C.",
"Language": "en",
"Country": "XG",
"Code": "Storage Conditions (Product)"
},
{
"Name": "Form of Supply",
"Value": "solid",
"Language": "en",
"Country": "XG",
"Code": "Form of Supply"
},
{
"Name": "Product Description",
"Value": "The adapter plate is for use with the LightCycler
® 480 System and the LightCycler
® 8-Tube Strips (white or clear).",
"Language": "en",
"Country": "XG",
"Code": "Product Description"
},
{
"Name": "Background Information - Help Corner",
"Value": "
Important Information LightCycler
® 8-Tube Strip Adapter Plate, was designed to allow the use of the latest generation of 8-Tube Strips on the LightCycler
® 480 Instrument. A new production technology was applied to the 8-Tube Strips to make them compatible with the instrument. To avoid problems when unloading those strips from the instrument, a certain product quality is needed to withstand thermal and mechanical stress applied to the disposable.
This product quality is reflected in the product batches defined below. To achieve best results, LightCycler
® 8-Tube Strips (white), Cat. No. 06 612 601 001 are recommended. These are available and can be ordered immediately. LightCycler
® 8-Tube Strips (clear), Cat. No. 06 327 672 001 will not be available until June 2014.
Please note that using strips other than specified below may result in loading issues, run aborts, or deformation of the 8-Tube Strips.
Please use the following batch numbers:
Due to an improved strip manufacturing process, a perfect fit can be guaranteed when using the LightCycler
® 8-Tube Strips with the following lot numbers:
• LightCycler
® 8-Tube Strips (white), Cat. No. 06 612 601 001 with
lot no. 13002411 and higher. • LightCycler
® 8-Tube Strips (clear), Cat. No. 06 327 672 001 with
lot no. 13008410 and higher. 13 describes the last two figures of the calendar year
002 / 008 describes a continuous 3-digit number of the current year. Every new year starts again with 001.
411 / 410 fixed part number
Handling Instructions For secure handling, place the LightCycler
® 8-Tube Strip Adapter Plate on top of a second LightCycler
® 8-Tube Strip Adapter Plate, or on top of a standard multiwell plate 96 (MWP).
Procedure The LightCycler
® 8-Tube Strip Adapter Plate can hold up to 12 LightCycler
® 8-Tube Strips.
- Pipet the reagent mix into the tubes of the LightCycler® 8-Tube Strips.
- Close the tubes by firmly pressing a strip of caps into place. Make sure that the tubes are closed properly, otherwise the contents could evaporate during the run.
- Centrifuge the filled and capped tube strips with the adapter plate inserted into the MWP or on top of an additional adapter plate at 1,500 × g for 2 min.
- Check that the centrifuged strips are not bent upwards on the end to avoid loading issues. Otherwise, press these flat in the adapter plate. A bending of approximately 4 mm in the middle of the strips is acceptable.
Cleaning Instructions If necessary, clean the LightCycler
® 8-Tube Strip Adapter Plate with 70% isopropanol. Alternatively, the adapter plate can be autoclaved.",
"Language": "en",
"Country": "XG",
"Code": "Background Information - Help Corner"
},
{
"Name": "Additional Equipment and Reagent Required",
"Value": "Additional equipment required to perform reactions using the LightCycler
® 8-Tube Strip Adapter Plate include:
- LightCycler® 480 Instrument II*
- LightCycler® 8-Tube Strips, white*, or clear*
- LightCycler® 480 Multiwell Plate 96 (white or clear)*, optional
- Standard swinging-bucket centrifuge containing a rotor for multiwell plates with suitable adaptor
",
"Language": "en",
"Country": "XG",
"Code": "Additional Equipment and Reagent Required"
},
{
"Name": "Content",
"Value": "
Label | Content |
---|
LightCycler® 8-Tube Strip Adapter Plate | 1 plate |
",
"Language": "en",
"Country": "XG",
"Code": "Content"
},
{
"Name": "Product Characteristics",
"Value": "The adapter plate is for use with the LightCycler
® 480 System and the LightCycler
® 8-Tube Strips (white or clear)",
"Language": "en",
"Country": "XG",
"Code": "Product Characteristics"
},
{
"Name": "Applications",
"Value": "The LightCycler 8-Tube Strip Adapter Plate can hold up to 12 LightCycler 8-Tube Strips in one run. The LightCycler
® 8-Tube Strip Adapter Plate can only be used with the LightCycler
® 480 Instrument I and LightCycler
® 480 Instrument II, 96-well version. The plate is not suitable for the use with LightCycler
® 96 Instruments.",
"Language": "en",
"Country": "XG",
"Code": "Applications"
}
]
}
}
]
}