{ "ProductData": { "ID": "3.5.5.1.5.4", "ProductType": "Others", "BrandName": "LightCycler® QC Kit", "ProductNameAddition": "", "RegulatoryDisclaimer1": "For general laboratory use.", "DisclaimerGroup1": "GLU", "RegulatoryDisclaimer2": null, "DisclaimerGroup2": null, "RegulatoryDisclaimer3": null, "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "LightCycler QC Kit" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/Article_03714055001_im_en.png", "ImageType": "Image main" }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "NodeID": "06-0022", "StructureNodeStatus": "Active", "NodeName": "LightCycler Carousel-based System Kits" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "NodeID": "90-000-00", "StructureNodeStatus": "Active", "NodeName": "Controls" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "NodeID": "230", "StructureNodeStatus": "Active", "NodeName": "LightCycler" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "NodeID": "100", "StructureNodeStatus": "Active", "NodeName": "Molecular" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "NodeID": "170-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "NodeID": "99-00-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "NodeID": "99-00-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "NodeID": "99-00-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "NodeID": "99-00-00", "StructureNodeStatus": "Inactive", "NodeName": "" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "NodeID": "999-00", "StructureNodeStatus": "Inactive", "NodeName": "" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "03714055001", "MaterialDescription": "LC QC Kit", "RegisteredProductName": "LightCycler QC Kit", "GTIN": "04038377020037", "ProductCategoryText": "Reagents, kits", "OldMaterialNumber": "", "PackSizePIM360": "1 kit", "PackSizeDescPIM360": "2 test runs", "MaterialAnnotation": "", "ReadyForUse": "", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Name": "Assay Time", "Value": "
ProcedureAssay Time [min]
PCR Set-up15
LightCycler® run55
Total assay time70
", "Language": "en", "Country": "XG", "Code": "Assay Time" }, { "Name": "Content", "Value": "
VialCapLabelFunction / DescriptionContent
1colorlessBlankMgCl2 solution1 vial
2greenMelting MixdsDNA fragments and detection dye1 vial
3purpleDetection MixPrimers, LightCycler® Red 640 labeled Hybridization Probe, fluorescein labeled Hybridization Probe1 vial
4redReaction MixTaq polymerase, reaction buffer1 vial
", "Language": "en", "Country": "XG", "Code": "Content" }, { "Name": "Product Description", "Value": "The LightCycler® QC Kit contains all reagents for test runs to verify the correct function of a LightCycler® Carousel-Based System Instrument.
The test comprises a blank for evaluation of the fluorimeter offset, Melting Mix for precise determination of temperature accuracy and several replicates of a weak PCR composition for analysis of instrument effects on PCR results.
The automated evaluation of raw data with the LightCycler® QC Software results in a detailed report with PASS/FAIL decision. In case of FAIL, the report contains hints for further investigation of a potential instrument malfunction.", "Language": "en", "Country": "XG", "Code": "Product Description" }, { "Name": "Product Purpose", "Value": "The LightCycler® QC Kit contains all reagents for test runs to verify the correct function of a LightCycler® Carousel-Based System Instrument.
The test comprises a blank for evaluation of the fluorimeter offset, Melting Mix for precise determination of temperature accuracy and several replicates of a weak PCR composition for analysis of instrument effects on PCR results.
The automated evaluation of raw data with the LightCycler® QC Software results in a detailed report with PASS/FAIL decision. In case of FAIL, the report contains hints for further investigation of a potential instrument malfunction.", "Language": "en", "Country": "XG", "Code": "Product Purpose" } ] } } ] }

LightCycler® QC Kit

Kit for Quality Control of the LightCycler® Carousel-Based System

GPR For general laboratory use.
LightCycler<sup>®</sup> QC Kit

Ordering Information

Overview

Technical Documents

Access Material Data Sheets, Certificates of Analysis, and other product documentation.

After clicking below, you will be redirected to eLabDoc, where you can choose your local country.

Instruments

...
    ...
    error errorMessage
    Sorry, we couldn't find the content you are looking for
    Please try again later