{ "ProductData": { "ID": "3.8.2.2.2.8", "ProductType": "Others", "BrandName": "MagNA Pure FFPET Buffer Set", "ProductNameAddition": "Buffer set for deparaffinization and lysis of formalin-fixed, paraffin-embedded tissue (FFPET) samples in automated and manual nucleic acid isolation workflows.", "RegulatoryDisclaimer1": "For general laboratory use.", "DisclaimerGroup1": "GPR", "RegulatoryDisclaimer2": "", "DisclaimerGroup2": null, "RegulatoryDisclaimer3": "", "SampleType": [ ], "LicenseDisclaimers": [ ], "RelatedLinks": "", "Clone": "", "ControlTissue": [ "" ], "ISOtypes": "", "Species": [ "" ], "StainLocalization": [ "" ], "ProductNameGlobal": "MagNA Pure FFPET Buffer Set" }, "ProductImageDetails": { "ImagePath": "https://pim-media.roche.com/Images/Article_08447144001_im_en.png", "ImageType": "Image main" }, "Product2Taxomony": { "Product2TaxomonyReferences": [ { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "StructureNodeStatus": "valid", "NodeName": "MagNA Pure Buffer & Kits", "NodeID": "06-0056" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "MagNA Pure", "NodeID": "260" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Auxiliaries", "NodeID": "95-000-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Molecular", "NodeID": "100" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "valid", "NodeName": "Sample Preparation", "NodeID": "130-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "170-00" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" } ] }, "Product2Taxonomy": { "Product2TaxonomyReferences": [ { "StructureSystemIdentifier": "Product_Grouping", "StructureSystemName": "Product Grouping", "StructureNodeStatus": "valid", "NodeName": "MagNA Pure Buffer & Kits", "NodeID": "06-0056" }, { "StructureSystemIdentifier": "OWP_Family", "StructureSystemName": "Product Families", "StructureNodeStatus": "valid", "NodeName": "MagNA Pure", "NodeID": "260" }, { "StructureSystemIdentifier": "OWP_Product_Types", "StructureSystemName": "Product Types", "StructureNodeStatus": "valid", "NodeName": "Auxiliaries", "NodeID": "95-000-00" }, { "StructureSystemIdentifier": "Product_Solutions", "StructureSystemName": "Product Solutions", "StructureNodeStatus": "valid", "NodeName": "Molecular", "NodeID": "100" }, { "StructureSystemIdentifier": "OWP_Techniques", "StructureSystemName": "Techniques", "StructureNodeStatus": "valid", "NodeName": "Sample Preparation", "NodeID": "130-00" }, { "StructureSystemIdentifier": "Lab_Type", "StructureSystemName": "Lab Types", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "170-00" }, { "StructureSystemIdentifier": "Applications", "StructureSystemName": "Applications", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Disease_Areas", "StructureSystemName": "Disease Areas", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Pathogens", "StructureSystemName": "Pathogens", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" }, { "StructureSystemIdentifier": "Health_Topics", "StructureSystemName": "Health Topics", "StructureNodeStatus": "invalid", "NodeName": "", "NodeID": "99-00-00" } ] }, "Product2Materials": { "P2MaterialReferences": [ { "MaterialNum": "08447144001", "MaterialDescription": "MagNA Pure FFPET Buffer Set", "RegisteredProductName": "MagNA Pure FFPET Buffer Set", "GTIN": "07613336157855", "ProductCategoryText": "Reagents, kits", "OldMaterialNumber": "", "PackSizePIM360": "1 kit", "PackSizeDescPIM360": "2 sets
To process up to 48 samples in automated workflows or up to 200 samples in manual pretreatment workflows", "MaterialAnnotation": "", "ReadyForUse": "false", "OrderInformation": "" } ] }, "Product2Products": { "Product2ProductReference": [ { "ProductID": "INS_2118", "BrandName": "MagNA Pure 96 Instrument", "ProductNameAddition": "High-throughput robotic workstation for fully automated purification of nucleic acids from up to 96 samples.", "ReferenceType": "Instrument", "Classification": [ { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "2329", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "260", "StructureGroupPath": "MagNA Pure", "StructureGroupName": "MagNA Pure", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "10-000-00", "StructureGroupPath": "Analyzer Instruments and Systems", "StructureGroupName": "Analyzer Instruments and Systems", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "241-00", "StructureGroupPath": "Nucleic Acid Extraction and Purification", "StructureGroupName": "Nucleic Acid Extraction and Purification", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "530", "StructureGroupPath": "Sequencing", "StructureGroupName": "Sequencing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "170-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "160-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "055", "StructureGroupPath": "Laboratory developed testing", "StructureGroupName": "Laboratory developed testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" } ] }, { "ProductID": "INS_6065", "BrandName": "MagNA Pure 24 Instrument", "ProductNameAddition": "A fully-automated clinical nucleic acid extraction system that brings you walkaway automation for up to 24 samples.", "ReferenceType": "Instrument", "Classification": [ { "IdentifierofStructureSystem": "1", "NameofStructureSystem": "GPCH", "StructureNodeID": "9302", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "" }, { "IdentifierofStructureSystem": "OWP_Family", "NameofStructureSystem": "Product Families", "StructureNodeID": "260", "StructureGroupPath": "MagNA Pure", "StructureGroupName": "MagNA Pure", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Product_Types", "NameofStructureSystem": "Product Types", "StructureNodeID": "10-000-00", "StructureGroupPath": "Analyzer Instruments and Systems", "StructureGroupName": "Analyzer Instruments and Systems", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "OWP_Techniques", "NameofStructureSystem": "Techniques", "StructureNodeID": "241-00", "StructureGroupPath": "Nucleic Acid Extraction and Purification", "StructureGroupName": "Nucleic Acid Extraction and Purification", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "530", "StructureGroupPath": "Sequencing", "StructureGroupName": "Sequencing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "170-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Lab_Type", "NameofStructureSystem": "Lab Types", "StructureNodeID": "160-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "055", "StructureGroupPath": "Laboratory developed testing", "StructureGroupName": "Laboratory developed testing", "StructureNodeStatus": "valid" }, { "IdentifierofStructureSystem": "Applications", "NameofStructureSystem": "Applications", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Pathogens", "NameofStructureSystem": "Pathogens", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Disease_Areas", "NameofStructureSystem": "Disease Areas", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Health_Topics", "NameofStructureSystem": "Health Topics", "StructureNodeID": "99-00-00", "StructureGroupPath": "", "StructureGroupName": "", "StructureNodeStatus": "invalid" }, { "IdentifierofStructureSystem": "Product_Solutions", "NameofStructureSystem": "Product Solutions", "StructureNodeID": "100", "StructureGroupPath": "Molecular", "StructureGroupName": "Molecular", "StructureNodeStatus": "valid" } ] } ] }, "ProductSpec": [ { "ProductSpecVariant": { "Chapters": [ { "Language": "en", "Value": "Store the set at +15 to +25°C.", "Country": "XG", "Code": "Storage Conditions (Product)", "Name": "Storage Conditions (Product)" }, { "Language": "en", "Value": "The MagNA Pure FFPET Buffer Set is used for the deparaffinization and lysis of FFPE tissue samples.
It is a safe alternative to xylene.", "Country": "XG", "Code": "Product Description", "Name": "Product Description" }, { "Language": "en", "Value": " 
Vial / BottleCapLabelFunction / DescriptionContent
1blackMagNA Pure FFPET Buffer Set,
Deparaffinization Reagent
Deparaffinizes FFPET samples.1 glass bottle,
50 mL
MagNA Pure FFPET Buffer Set,
Deparaffinization Reagent
  • Barcoded empty bottles.
  • To transfer deparaffinization reagent for automated workflows or for aliquoting.
2 reagent bottles,
for 25 mL each
2blackMagNA Pure FFPET Buffer Set,
Lysis Buffer
Lyses deparaffinized tissue.2 bottles,
22 mL each
3blackMagNA Pure FFPET Buffer Set,
Isopropanol
Enhance binding of nucleic acids to MGP.4 bottles,
22 mL each
", "Country": "XG", "Code": "Content", "Name": "Content" }, { "Language": "en", "Value": "Buffer set for deparaffinization and lysis of formalin-fixed, paraffin-embedded tissue (FFPET) samples in automated and manual nucleic acid isolation workflows.", "Country": "XG", "Code": "Product Characteristics", "Name": "Product Characteristics" }, { "Language": "en", "Value": "
For manual pretreatment
Hands-on timeApproximately 10 minutes for 8 samples
Total processing timeApproximately 105 minutes for 8 samples
", "Country": "XG", "Code": "Assay Time", "Name": "Assay Time" }, { "Language": "en", "Value": "The MagNA Pure FFPET Buffer Set is intended for the:
  • Deparaffinization and lysis of formalin-fixed, paraffin-embedded tissue samples in automated and manual nucleic acid isolation workflows.
    With an optimized chemistry and protocol, the set eliminates the need to incubate FFPET samples overnight or to use xylene.
", "Country": "XG", "Code": "Applications", "Name": "Applications" } ] } } ] }

MagNA Pure FFPET Buffer Set

Buffer set for deparaffinization and lysis of formalin-fixed, paraffin-embedded tissue (FFPET) samples in automated and manual nucleic acid isolation workflows.

MagNA Pure FFPET Buffer Set

Ordering Information

Overview

Technical Documents

Access Material Data Sheets, Certificates of Analysis, and other product documentation.

After clicking above, you will be redirected to eLabDoc, where you can choose your local country.

Instruments

...
    ...
    error errorMessage
    Sorry, we couldn't find the content you are looking for
    Please try again later